2.1.1.3-247

New features

  • Parameter: Settable voltage measurement threshold.
  • HMI: Transformer module measurements added to mimic.
  • HMI: Imeas/Iset to I2> function.
  • HMI: Kazakh, Chinese and Russian language translations.
  • Communication: Energy measurement mapping to IEC61850.
  • Communication: Scaled analog inputs to IEC104.
  • Communication: Voltage and current THD to IEC61850.
  • Communication: U3/U4 frequency to IEC61850 and Modbus.
  • Communication: CTS2 to IEC61850 mapping.
  • Communication: Programmable stages to IEC61850.

Changes

  • Synchrocheck [25]: Added LL/DL/LD/DD-mode, ability to select line or bus as reference, additional signals.

Corrections

  • mA output: Corrected mA output accuracy.
  • Frequent start FSP (N>) [66]:Fixed issue where frequency start -stage was not working correctly.
  • AVR: Fixed issue where AVR scaling curve was not working correctly.
  • Communication: Fixed issues with IEC61850 Test outs (forced statuses) and events.
  • Directional overcurrent (Idir>) [67]: Fixed issue where protection blocking signal reset start signal to zero.
  • HMI: Corrected language encoding.
  • Synchrocheck: Fixed issue where synchrocheck was not working correctly with maximum settings.
  • TrafoModule: Fixed issue where Manual Set vector group was not working correctly.
  • General: Improved USW connection termination.
  • General: Improved option card detection.
  • General: Fixed issue where device discovery announcement message had incorrect serial number.

2.1.1.3-247

10/01/2025

New features

  • Parameter: Settable voltage measurement threshold.
  • HMI: Transformer module measurements added to mimic.
  • HMI: Imeas/Iset to I2> function.
  • HMI: Kazakh, Chinese and Russian language translations.
  • Communication: Energy measurement mapping to IEC61850.
  • Communication: Scaled analog inputs to IEC104.
  • Communication: Voltage and current THD to IEC61850.
  • Communication: U3/U4 frequency to IEC61850 and Modbus.
  • Communication: CTS2 to IEC61850 mapping.
  • Communication: Programmable stages to IEC61850.

Changes

  • Synchrocheck [25]: Added LL/DL/LD/DD-mode, ability to select line or bus as reference, additional signals.

Corrections

  • mA output: Corrected mA output accuracy.
  • Frequent start FSP (N>) [66]:Fixed issue where frequency start -stage was not working correctly.
  • AVR: Fixed issue where AVR scaling curve was not working correctly.
  • Communication: Fixed issues with IEC61850 Test outs (forced statuses) and events.
  • Directional overcurrent (Idir>) [67]: Fixed issue where protection blocking signal reset start signal to zero.
  • HMI: Corrected language encoding.
  • Synchrocheck: Fixed issue where synchrocheck was not working correctly with maximum settings.
  • TrafoModule: Fixed issue where Manual Set vector group was not working correctly.
  • General: Improved USW connection termination.
  • General: Improved option card detection.
  • General: Fixed issue where device discovery announcement message had incorrect serial number.

On this page, you can download software updates for your product(s) and help yourself to various utility tools and add-ons that will assist you in setting up, detecting faults and configuring your product(s).

Please be advised that not all of our products can be updated by the user. Nor do all of our products come with a utility tool. Consequently, the list on this page cannot be considered an overview of our product programme.

DEIF will register your download along with the used e-mail address for the purpose of sending out information on future updates, if requested.

DEIF cannot be made responsible for any consequences of failed product updates or use of utility tools. Nor can DEIF A/S be made responsible for consequences of changes in behaviour of products due to a software upgrade. It is always the responsibility of the user to ensure correct set-up and configuration before commissioning. Please study the version log of the software before updating the product.

Licence agreement for software downloaded from www.deif.com

Downloaded software remains the property of DEIF. The software may not be distributed for commercial purposes, changed or reused in full or in part or sold to any third parties.

The latest versions for full functionality

As always, we recommend that you install our offered improvements to fully utilise your DEIF product.

All improved software can be downloaded at your convenience at www.deif.com under “Software”.

Should you have any questions or experience problems finding the relevant software for your product, please feel free to call DEIF A/S at +45 96149614 or your relevant local DEIF office. Alternatively, we are always ready to assist you, if you send an e-mail to support@deif.com.